MOTOR DHK8000
305
400
DOWNDRAFT HOODS
50
220x90
230x80
INSTALLATION GUIDELINES
Installation is possible with all hobs including gas hobs.
To install inside a cabinet, you must remove the
motor, place the hood on top and secure the motor
block back. The latter can be placed at the front or
at the back of the hood with a horizontal or vertical
vent. For a recycling installation, a vent will be
required inside the cabinet, under the cabinets, or
by making a hole in the side of the cabinet (the vent
tube and hooks are not provided). The electronic
control unit must be placed in an easily accessible
area 10cm from the ground and away from any
source of heat. Once installation is complete, the
automatic calibration of the hood must be carried
out. Finally, for optimal effi ciency, the authorised
distance between the recess hole for the hood and
the counter top is maximum 6cm.
KIT TO REMOVE THE MOTOR: DHK900
The kit contains:
2 connection fl anges diam. 150mm
8 screws and 8 retaining nuts
1 7m-long extension cord to plug
in the motor
1 plastic connector, rectangle or round
1 side/lower connector for the tube
1 zinc plated steel sheet for the back
1 2m-long tube for air ventilation
MOTOR DHK9000
TECHNICAL SPECIFICATIONS
179
330
400
8
110
230x80
220x90
218x55
5 possible vent
positions